DIGITALNA ARHIVA ŠUMARSKOG LISTA
prilagođeno pretraživanje po punom tekstu




ŠUMARSKI LIST 9-10/1999 str. 58     <-- 58 -->        PDF

T. Dimitrov: ŠUMSKI POŽARI U HRVATSKOJ POVOD ZA RAZMIŠLJANJE Šumarski list br. 9-10, CXXIII(1999), 461-468
Na slikama su prikazana dva praktična primjera upociju
o jačini čelne vatrene fronte od 1 685 kW/m, a u


rabe FBP sustava kod eksperimentalnih šumskih požara drugom (slika 3) o jačini čelne fronte od 17 777 kW/m.
najednom lokalitetu s istim tipom goriva (crna smreka-Za uspjelo suzbijanje tih požara potpuno su različite
lišaj), ali s različitim ulaznim meteorološkim elementi


potrebe u ljudstvu i materijalno-tehničkim sredstvima.
ma. U prvom slučaju (slika 2) FBP sustav daje informa


Experimental Fire: L4 Dale: July 6 Photo: G.P. Delisle


Fire Weather Observations F HI System Fuel Moisture Codes Description of Fire Behavior:


Dry-bulb temperature 21.5°C Fine Fuel Moisture Code (FFMC) 90.1 Fire spread more or less continuous
Relative humidity 36% Duff Moisture Code (DMC) 55 across the plot area. Sporadic torching
10-m open wind 14.5 km/ h Drought Code (DC) 247 experienced at favorable locations.
Days since rain 3 Smouldering black spruce needles
and bark flakes were carried up to
FWI System Fire Behavior Indexes Fire Behavior Characteristics 15 m ahead of the flaming trees.
Downed-dead woody fuels served to


Initial Spread Index (ISI) 9.1 | lead fire rate of spread 3.7 m/min


reinforce the spread rate.


Buildup Index (BUI) 71 Fuel consumption 1.53 kg/nv
Fire Weather Index (FWI) 25 FrontalTire intensity 1685 kW/ m Type of the Fire: Intermittent crown fire


Slika 2: Eksperimentalni požar L4, s jačinom čelne vatrene fronte od 1 685 kW/m.


Experimental Fire: L5 Date: July 7 Photo: B.D. Lavvson


Fire Weather Observations FWI System Fnet Moisture Codes Description of Fire Behavior:


Dry-bulb temperature 27.5°C Fine Fuel Moisture Code (FFMC) 92.0 Initially, intense radiant heat experiRelative
humidity 3 I % Duff Moisture Code (DMC) 59 enced up to 30 m downwind of tor10-
m open wind 28.0 km/h Drought Code (DC) 256 ching black spruce clumps. Spot fires
Days since rain 4 developed a further 20 m away. As a
result, fire accelerated very quickly,
involving many trees together, with


FWI System Fire Behavior Indexes Fire Behavior Characteristics


flames about 15-20 m high.
Initial Spread Index (ISI) 23.5 Head fire rate of spread 33.3 m/min
Buildup Index (BUI) 75 Fuel consumption 1.81 kg/m2
Fire Weather Index (FWI) 48 Frontal Are intensity 17 777 kW/m Type of Fire: Fully developed crown fire


Slika 3: Eksperimentalni požar L5, s jačinom čelne vatrene fronte od 17 777 kW/m.